Treatment of insufficient lift of slurry pump
(1) The filling slurry pump is insufficient (or the slurry pump gas is not set >. Treatment method: filled with slurry pump
(2) The slurry pump rotation is not correct. Treatment method: Check hand rotation,
(3) The speed of slurry pump is too low. Treatment method: Check the rotation speed and increase the speed:
(4) Mesh interference, the bottom valve does not work. Treatment method: Check the grid, eliminate debris,
(5) Air leakage in the suction pipe of the slurry pump. Treatment method: Check the sealing of the suction side pipe connection point and the packing box.
(6) The impeller of theslurry pump is blocked, worn and corroded. Treatment method: clean, check, replace;
(7) Install reverse (double suction impeller rotation). Treatment method: check the impeller,
(8) The liquid density and viscosity of the slurry are inconsistent with the design conditions. Treatment method: Check the physical properties of the liquid:
(9) The slurry pump operating current capacity is too large, treatment method: reduce the current capacity.
Next: What is caused by the vertical slurry pump without water